Airway counts PCA

Inputs: gene-level counts and sample sheet from the CSAMA airway teaching files.
Design check: 4 donors, each with exactly one untrt and one trt sample.
Library size: sum of all input genes per sample; CPM = counts / library size * 1e6.
Gene filter: kept genes with CPM >= 1 in at least 2 samples.
Transform: log2(CPM+1); each gene centered across samples, no scaling.
PCA: SVD of the gene-centered genes x samples matrix; sample scores = V * S.
Variance explained = S^2 / sum(S^2). SVD sign is arbitrary and fixed by convention.
Arrows connect untrt to trt within a donor and describe this paired set of observations only.
No statistical test, causal claim, or clinical efficacy claim is made.